Troubleshooting118
3078 Diag get drive 0 status failed
(Failed to get drive status, communication
error.)
• Press the Enter button to reboot.
• Ensure the drive shows good status
through the drive status window.
• Deactivate the drive using the GUI control
panel maintenance menu.
• Reseat drive.
• Check cabling.
• Load/unload a cartridge to the drive to
verify.
• Check the tape cartridge used in the last
operation for damage.
• Run the cartridge cycle diagnostic to
verify.
3079 Diag get drive 1 status failed
(Failed to get drive status, communication
error.)
• Press the Enter button to reboot.
• Ensure the drive shows good status
through the drive status window.
• Deactivate the drive using the GUI control
panel maintenance menu.
• Reseat drive.
• Check cabling.
• Load/unload a cartridge to the drive to
verify.
• Check the tape cartridge used in the last
operation for damage.
• Run the cartridge cycle diagnostic to
verify.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP