466
*1 These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 333 for RS-485 communication)
*2 Validity and invalidity according to operation mode are as follows:
:Usable parameter
×:Unusable parameter
Δ:Parameters available only during position control set by parameter
*3 "" indicates valid and "
×" indicates invalid of "parameter copy", "parameter clear", and "all parameter clear".
*4 Parameters can be used with conditions. Refer to page 203 for details.
*5 These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication.
(Refer to page 328 for RS-485 communication)
*6 When a communication option is installed, parameter clear (lock release) during password lock (Pr. 297 ≠ 9999) can be performed only from the
communication option.
Symbols in the table indicate parameters which function when an option is mounted.
......FR-A7AX, ......FR-A7AY, .............FR-A7AR, .........FR-A7AP, ..........FR-A7AL, .........FR-A7AZ, .........FR-A7AD,
......FR-A7NC, ......FR-A7NCE, .........FR-A7ND, .........FR-A7NL, .........FR-A7NP, .........FR-A7NS, .........FR-A7NF
Appendix 2 Control mode-based parameter (function) correspondence
table and instruction code list
Parameter
Name
Instruction
Code
* 1
Control Mode-based Correspondence Table *2
Parameter Copy
*3
Parameter Clear
*3
All Parameter Clear
*3
Read
Write
Extended
V/F
control
Advanced
magnetic
flux
vector
control
Vector control
Real sensorless
vector control
Speed
control
Torque
control
Position
control
Speed
control
Torque
control
0
Torque boost
00 80 0
× ×××××
1
Maximum frequency
01 81 0
2
Minimum frequency
02 82 0
×
3 Base frequency
03 83 0
× × × × × ×
4
Multi-speed setting (high speed)
04 84 0
Δ
5
Multi-speed setting (middle speed)
05 85 0
Δ
6
Multi-speed setting (low speed)
06 86 0
Δ
7
Acceleration time
07 87 0
Δ
8
Deceleration time
08 88 0
Δ
9 Electronic thermal O/L relay
09 89 0
10
DC injection brake operation
frequency
0A 8A 0
×
11
DC injection brake operation
time
0B 8B 0
×
12
DC injection brake operation
voltage
0C 8C 0
×××*4 *4
13
Starting frequency
0D 8D 0
×
14
Load pattern selection
0E 8E 0
× ×××××
15 Jog frequency
0F 8F 0
×
16
Jog acceleration/
deceleration time
10 90 0
×
17 MRS input selection
11 91 0
18
High speed maximum
frequency
12 92 0
×××××
19 Base frequency voltage
13 93 0
× × × × × ×
20
Acceleration/deceleration
reference frequency
14 94 0
Δ
21
Acceleration/deceleration
time increments
15 95 0
Δ
22
Stall prevention operation
level (torque limit level )
16 96 0
× ×
23
Stall prevention operation
level compensation factor at
double speed
17 97 0
× × × × ×
24
Multi-speed setting (speed
4)
18 98 0
Δ
25
Multi-speed setting (speed 5)
19 99 0
Δ