![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/a1/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6-bg5a.png)
Parameter listParameter list
80
5
PARAMETERS
Parameter List
— 30 Regenerative function selection 0, 1, 2 1 0
136,
151
30 {{{{{
Frequency jump
31 Frequency jump 1A 0 to 400Hz, 9999 0.01Hz 9999 106 31 { { { { {
32 Frequency jump 1B 0 to 400Hz, 9999 0.01Hz 9999 106 32 {{{{{
33 Frequency jump 2A 0 to 400Hz, 9999 0.01Hz 9999 106 33 { { { { {
34 Frequency jump 2B 0 to 400Hz, 9999 0.01Hz 9999 106 34 {{{{{
35 Frequency jump 3A 0 to 400Hz, 9999 0.01Hz 9999 106 35 { { { { {
36 Frequency jump 3B 0 to 400Hz, 9999 0.01Hz 9999 106 36 {{{{{
— 37 Speed display 0, 0.01 to 9998 0.001 0 146 37 { { { { {
— 40 RUN key rotation direction selection 0, 1 1 0 182 40 {{{{{
Frequency
detection
41 Up-to-frequency sensitivity 0 to 100% 0.1% 10% 144 41 { { { { {
42 Output frequency detection 0 to 400Hz 0.01Hz 6Hz 144 42 {{{{{
43
Output frequency detection for reverse
rotation
0 to 400Hz, 9999 0.01Hz 9999 144 43 { { { { {
Second functions
44 Second acceleration/deceleration time 0 to 3600/360s 0.1/0.01s 5/10/15s ∗2 116 44 {{{{{
45 Second deceleration time 0 to 3600/360s, 9999 0.1/0.01s 9999 116 45 { { { { {
46 Second torque boost 0 to 30%, 9999 0.1% 9999 94 46 { ××{{
47 Second V/F (base frequency) 0 to 400Hz, 9999 0.01Hz 9999 107 47 { × × { {
48
Second stall prevention operation
current
0 to 200%, 9999 0.1% 9999 101 48 {{{{{
51 Second electronic thermal O/L relay 0 to 500A, 9999 0.01A 9999 123 51 { { { { {
— 52 DU/PU main display data selection
0, 5, 7 to 12, 14, 20,
23 to 25, 52 to 57, 61,
62, 100
10147 52 {{{{{
— 54
Parameter for manufacturer setting. Do not set.
54
Parameter for manufacturer setting. Do not set.—55 55
— 56 56
Automatic restart
functions
57 Restart coasting time 0, 0.1 to 5s, 9999 0.1s 9999 151 57 {{{{{
58 Restart cushion time 0 to 60s 0.1s 1s 151 58 { { { { {
— 59 Remote function selection 0, 1, 2, 3 1 0 113 59 {{{{{
— 60 Energy saving control selection 0, 9 1 0 162 60 { × × { {
Automatic acceleration
/deceleration
61 Reference current 0 to 500A, 9999 0.01A 9999 121 61 {{{{{
62 Reference value at acceleration 0 to 200%, 9999 1% 9999 121 62 { { { { {
63 Reference value at deceleration 0 to 200%, 9999 1% 9999 121 63 {{{{{
— 65 Retry selection 0 to 5 1 0 158 65 { { { { {
—66
Stall prevention operation reduction
starting frequency
0 to 400Hz 0.01Hz 60Hz 101 66 {{{{{
Retry
67 Number of retries at fault occurrence 0 to 10, 101 to 110 1 0 158 67 { { { { {
68 Retry waiting time 0.1 to 360s 0.1s 1s 158 68 {{{{{
69 Retry count display erase 0 1 0 158 69 { { { { {
— 70 Special regenerative brake duty 0 to 30% 0.1% 0% 136 70 {{{{{
— 71 Applied motor
0, 1, 3 to 6, 13 to 16, 23,
24, 40, 43, 44, 50, 53, 54
1 0
95, 98,
125,
127,
71 { { { { {
— 72 PWM frequency selection 0 to 15 1 1 163 72 {{{{{
— 73
Parameter for manufacturer setting. Do not set.
73
Parameter for manufacturer setting. Do not set.
—74 74
— 75 Reset selection/PU stop selection 0 to 3, 14 to 17 1 14 165 75 { { { × ×
— 77∗6 Parameter write selection 0, 1, 2 1 0 166 77 {{{{{
— 78 Reverse rotation prevention selection 0, 1, 2 1 0 167 78 { { { { {
— 79 Parameter for manufacturer setting. Do not set. 79 Parameter for manufacturer setting. Do not set.
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC