Parameter listParameter list
86
5
PARAMETERS
Parameter List
Stop-on
contact
control
275
Stop-on contact excitation current low-
speed multiplying factor
0 to 300%, 9999 0.1% 9999 139 275 × {{{{
276
PWM carrier frequency at stop-on
contact
0 to 9, 9999 1 9999 139 276 × { { { {
— 277
Stall prevention operation current
switchover
0, 1 1 0 101 277 {{{{{
— 278
Parameter for manufacturer setting. Do not set.
278
Parameter for manufacturer setting. Do not set.
— 279 279
— 280 280
— 281 281
— 282 282
— 283 283
Droop
control
286 Droop gain 0 to 100% 0.1% 0% 173 286 × { × { {
287 Droop filter time constant 0 to 1s 0.01s 0.3s 173 287 × { × {{
— 292 Automatic acceleration/deceleration 0, 1, 7, 8, 11 1 0 121 292 { { { { {
— 293
Acceleration/deceleration separate
selection
0 to 2 1 0 121 293 {{{{{
— 295 Magnitude of frequency change setting 0, 0.01, 0.1, 1, 10 0.01 0 185 295 { { { { {
Password
function
296 Password lock level
0 to 6, 99, 100 to 106,
199, 9999
1 9999 169 296 {{{× {
297 Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1 9999 169 297 { { { × {
— 298 Frequency search gain 0 to 32767, 9999 1 9999 151 298 {{{× {
— 299
Rotation direction detection selection
at restarting
0, 1, 9999 1 0 151 299 { { { { {
— 338
Parameter for manufacturer setting. Do not set.
338
Parameter for manufacturer setting. Do not set.
— 339 339
— 340 340
— 342 342
— 343 343
Second motor
constant
450 Second applied motor 0, 1, 9999 1 9999 125 450 { { { { {
— 495
Parameter for manufacturer setting. Do not set.
495
Parameter for manufacturer setting. Do not set.
— 496 496
— 497 497
— 500 500
— 501
Communication error occurrence count
display
010161 501 {{{{{
— 502 Parameter for manufacturer setting. Do not set. 502 Parameter for manufacturer setting. Do not set.
Maintenance
503 Maintenance timer 0 (1 to 9998) 1 0 180 503 {{{××
504
Maintenance timer alarm output set
time
0 to 9998, 9999 1 9999 180 504 { { { × {
— 547
Parameter for manufacturer setting. Do not set.
547
Parameter for manufacturer setting. Do not set.
— 548 548
— 549 549
— 550 550
— 551 551
— 555 555
— 556 556
— 557 557
— 563 Energization time carrying-over times (0 to 65535) 1 0 147 563 {{{××
— 564 Operating time carrying-over times (0 to 65535) 1 0 147 564 { { { × ×
— 571 Holding time at a start 0 to 10s, 9999 0.1s 9999 119 571 {{{{{
— 611 Acceleration time at a restart 0 to 3600s, 9999 0.1s 9999 151 611 { { { { {
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC