![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/a1/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6-bg5b.png)
Parameter listParameter list
82
5
PARAMETERS
Parameter List
Motor constants
80 Motor capacity 0.1 to 15kW, 9999 0.01kW 9999
93, 95,
98,
127
80 × { { { {
81 Number of motor poles 2, 4, 6, 8, 10, 9999 1 9999
93, 95,
98,
127
81 × {{{{
82 Motor excitation current
0 to 500A (0 to ****), 9999
∗5
0.01A (1) ∗5 9999 127 82 × { { × {
83 Rated motor voltage 0 to 1000V 0.1V
200V/400V
∗4
127 83 × {{{{
84 Rated motor frequency 10 to 120Hz 0.01Hz 60Hz 127 84 × { { { {
89
Speed control gain (Advanced
magnetic flux vector)
0 to 200%, 9999 0.1% 9999 95 89 × { ××{
90 Motor constant (R1)
0 to 50Ω (0 to ****) ,
9999
∗5
0.001Ω (1) ∗5 9999 127 90 { { { × {
91 Motor constant (R2)
0 to 50Ω (0 to ****) ,
9999
∗5
0.001Ω (1) ∗5 9999 127 91 × {{× {
92 Motor constant (L1)
0 to 1000mH (0 to 50Ω,
0 to ****), 9999
∗5
0.1mH
(0.001Ω, 1)
∗5
9999 127 92 × { { × {
93 Motor constant (L2)
0 to 1000mH (0 to 50Ω,
0 to ****) , 9999
∗5
0.1mH
(0.001Ω, 1)
∗5
9999 127 93 × {{× {
94 Motor constant (X)
0 to 100% (0 to 500Ω, 0
to ****) , 9999
∗5
0.1%
(0.01Ω, 1)
∗5
9999 127 94 × { { × {
96 Auto tuning setting/status 0, 1, 11, 21 1 0
127,
151
96 {{{× {
— 117
Parameter for manufacturer setting. Do not set.
117
Parameter for manufacturer setting. Do not set.
—118 118
— 119 119
— 120 120
— 121 121
— 122 122
— 123 123
— 124 124
— 125 125
— 126 126
— 127 127
— 128 128
— 129 129
— 130 130
— 131 131
— 132 132
— 133 133
— 134 134
— 145 145
— 146 146
— 147
Acceleration/deceleration time
switching frequency
0 to 400Hz, 9999 0.01Hz 9999 116 147 { { { { {
Current
detection
150 Output current detection level 0 to 200% 0.1% 150% 145 150 {{{{{
151
Output current detection signal delay
time
0 to 10s 0.1s 0s 145 151 { { { { {
152 Zero current detection level 0 to 200% 0.1% 5% 145 152 {{{{{
153 Zero current detection time 0 to 1s 0.01s 0.5s 145 153 { { { { {
— 156 Stall prevention operation selection 0 to 31, 100, 101 1 0 101 156 {{{{{
— 157 OL signal output timer 0 to 25s, 9999 0.1s 0s 101 157 { { { { {
— 160 User group read selection 0, 1, 9999 1 0 167 160 {{{{{
— 161
Frequency setting/key lock operation
selection
0, 1, 10, 11 1 0 183 161 { { { × {
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC