![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/a1/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6/da19e8fc-ef37-47b2-8bef-a7ab4554d9a6-bg5e.png)
Parameter listParameter list
88
5
PARAMETERS
Parameter List
— 653 Speed smoothing control 0 to 200% 0.1% 0 164 653 {{{{{
— 665
Regeneration avoidance frequency
gain
0 to 200% 0.1% 100 174 665 { { { { {
— 800 Control method selection 20, 30 1 20
93, 95,
98
800 × {{{{
— 859 Torque current
0 to 500A (0 to ****) ,
9999
∗5
0.01A (1) ∗5 9999 127 859 × { { × {
Protective
functions
872 Input phase loss protection selection 0, 1 1 1 160 872 {{{{{
Regeneration avoidance
function
882
Regeneration avoidance operation
selection
0, 1, 2 1 0 174 882 { { { { {
883
Regeneration avoidance operation
level
300 to 800V 0.1V
400VDC/
780VDC
∗4
174 883 {{{{{
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999 0.01Hz 6Hz 174 885 { { { { {
886 Regeneration avoidance voltage gain 0 to 200% 0.1% 100% 174 886 {{{{{
Free
parameter
888 Free parameter 1 0 to 9999 1 9999 181 888 { { { × ×
889 Free parameter 2 0 to 9999 1 9999 181 889 {{{××
— C0
Parameter for manufacturer setting. Do not set.
C0
Parameter for manufacturer setting. Do not set.
—C2 C2
— C3 C3
—C4 C4
— C5 C5
—C6 C6
— C7 C7
—C22 C22
— C23 C23
—C24 C24
— C25 C25
— 990 990
— 991 991
Clear parameters
Initial value change list
Pr.CL Parameter clear 0, 1 1 0 186 Pr.CL — — — — —
ALLC All parameter clear 0, 1 1 0 186 ALLC — — — — —
Er.CL Faults history clear 0, 1 1 0 188 Er.CL — — — — —
Pr.CH Initial value change list — — — 187 Pr.CH — — — — —
∗1 Differ according to capacities.
6%: 0.75K or lower
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K, 15K
∗2 Differ according to capacities.
5s: 3.7K or lower
10s: 5.5K, 7.5K
15s: 11K, 15K
∗3 Differ according to capacities.
6%: 0.1K, 0.2K
4%: 0.4K to 7.5K
2%: 11K, 15K
∗4 The initial value differs according to the voltage class. (200V class/400V class)
∗5 The range differs according to the Pr. 71 setting.
∗6 The setting cannot be changed through FL remote communication.
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC