LCD ERROR SCREENS
Set Temp. Current Temp.
BOT:150*F BOT:098*F
MODE:FWRD GAP:000%
ESW SW PRESSED!!!
TOP:150*F TOP:098*F
FIGURE 1.
FIGURE 2.
FIGURE 3.
FIGURE 4.
FIGURE 1:
ESW SW PRESSED!!! -Indicates that an
Emergency Stop is activated. Locate the
Emergency Stop and release it. This will return
the machine to normal operating condition.
FIGURE 2:
SAFETY INTERLOCKED!!! -Indicates that a
Table Inter lock is not positioned correctly. Locate
the Table Inter-locks and verify that they are
activating the Micro-Switch. Once the Table
Inter-Lock is positioned correctly the machine will
return to normal operating condition.
FIGURE 3:
TOP HTR ERR!!! -Indicates that the Top
Temperature has exceeded the set point drastically.
Verify that the IR Sensors are not blocked. If they
are blocked by film or media, remove the film or
media…press and hold the Master Dial on the
Control Panel. The machine will return to normal
operating condition.
FIGURE 4:
BOT HTR ERR!!! -Indicates that the Bottom
Temperature has exceeded the set point drastically.
Verify that the IR Sensors are not blocked. If they
are blocked by film or media, remove the film or
media…press and hold the Master Dial on the
Control Panel. The machine will return to normal
operating condition.