ACCO Brands GBC 2064WF-1 Range User Manual


 
GBC 2064WF-1 Operation Manual
© 2009 General Binding Corporation an ACCO Brands CO. Page 8
CONTROL GUIDE
Speed
Stop
Bottom Temp
Top Temp
Forward
Rear
Cooling
MASTER DIAL
Meas.
Reset
Set Temp. Current Temp.
TOP: 150*F
BOT: 150*F
TOP: 140*F
TOP: 145*F
MODE: FWRD
SPEED: 08ft
GAP: 000%
PRS: 030%
1
2
3
4
56
7
8
91011
FIGURE 1
A. Power ON/OFF (I/O):
Located at the back left of the machine applies power to
the laminator. The control panel display will illuminate
when position marked “I” is pushed. The Off position,
marked “O” removes power from the laminator.
B. Control Panel (FIGURE 1)
1. Main display Read out:
Illuminates when the laminator is plugged in and
POWER ON/OFF is in the on, (I), position.
Displays settings for the top heater, bottom
heater, speed, job mode, and ready/wait.
TOP: Refers to the Top Main Rollers
temperatures setting and Current Temperature.
BOT: Refers to the Bottom Main Rollers
temperatures setting and Current Temperature.
MODE: Displays the Direction the rollers are set
to... In FIGURE 5, the MODE is shown in the
FWRD” position.
SPEED: Speed is displayed in Feet per Minute or
ft/mn. FIGURE 5 Displays the Speed set at 8ft.
GAP: As the rollers are lifted, the GAP is
measured digitally. The value is shown as a
percentage. No GAP equals 000%, completely in
the up positions equals 100%.
PRS: PRS refers to the amount of downward
pressure being applied to the Main Rollers. The
value is shown as a percentage. FIGURE 5
shows the PRS is set for 30%. No Pressure will
equal 000%, maximum pressure will read 100%.
2. Master Dial:
Increases (+) or decreases (-) the numeric
value for the selected setting when turned.
3. Top Temp:
When pressed, permits increasing or
decreasing of the top set temperature by
turning the MASTER DIAL and is indicated
on the control panel display. Range is 32°F-
300°F.
4. Bottom Temp:
When pressed, permits increasing or
decreasing of the bottom set temperature by
turning the MASTER DIAL and is indicated
on the control panel display. Range is 32°F-
300°F.
5. Speed:
When pressed, permits increasing or
decreasing of speed by turning the MASTER
DIAL and is indicated on the control panel
display. Range is 1-15.
6. Cooling:
When pressed, turns on the cooling fans.
When pressed again, turns off the cooling fans.
7. Measure:
When pressed, allows the operator to view the
amount of linear feet that the machine has run.
8. Reset:
When pressed, permits the operator to rest the
linear feet counter.
9. Stop:
When pressed, the rollers will stop rotating.
10. Rear:
When pressed, the rollers will allow the
operator to run the machine in reverse or the
rear.
11. Forward:
When pressed, the rollers will allow the
operator to run the machine in forward mode
or from the front.