Aga Ranges U104001-03 Range User Manual


 
39
Read all instructions before installing or using this appliance.
Installation Instructions
Save these instructions for future reference.
Slide the cover down to free the side tags.
Free from the bottom tag.
When refi tting the cover fi rst locate it on the
bottom tag second locate the two side tags and
then replace the screws.
4-Wire Conduit Installation
Disconnect the supplied power cord from
the terminal block and ground post. Keep
the terminal block parts; you will need them.
Remove the strain relief clamp from the power
cord and remove the power cord and strain relief
clamp from the mounting bracket.
The range is shipped with reducer plates to
give a 1 1/8’’ diameter opening for conduit
connection. Find the reducer plates in the
conversion kit and fi t them to the mounting
bracket.
Fit a squeeze connector (not supplied with
the range), to your conduit. Insert the conduit
through the reducer plates on the mounting
bracket. Allow enough slack to easily attach the
wires to the terminal block.
NOTE: Do not install the conduit without a
squeeze connector.
Fit the wires to the ground post and terminal
block
NOTE: Make sure the wires are completely
inserted into the terminals and secure
connections are made.
Secure the squeeze connector in place in the
bracket by tightening the squeeze connector
screws.
Refi t the electrical connection cover.
Fitting a 3-Wire Power Cord
Disconnect the supplied power cord from
the terminal block and ground post. Keep
the terminal block parts; you will need them.
Remove the strain relief clamp from the power
cord and remove the power cord and strain relief
clamp from the mounting bracket. Discard the
strain relief clamp.
NOTE: Do not install the power cord without
a strain relief - use the clamp supplied
with the cord.