Alto-Shaam 1218ESG Oven User Manual


 
COMBITOUCH
®
ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 14.
INSTALLATION
ELECTRICAL
An electrical wiring diagram is located behind the
control panel on the left side of the oven. This appliance
must be branch circuit protected with proper ampacities,
in accordance with the wiring diagram.
Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven model.
For supply connections, locate the wire size posted
on the label located on the electrical control box
cover, behind the service panel.
Before operating the oven, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After both water and electrical
connections have been completed, operate
the oven in any cooking mode for a period
of 15 minutes and recheck the main power
connections at the terminal block to make
certain they remain tight.
380-415V:
MODEL VOLTAGE PHASE CIRCUIT AWG
6•10esG 110-120 1 20 A 2 WIRE
7•14esG 110-120 1 20 A 2 WIRE
10•10esG 110-120 1 20 A 2 WIRE
10•20esG 110-120 1 20 A 2 WIRE
12•18esG 110-120 1 20 A 2 WIRE
20•20esG 110-120
208-240
208-240
1
1
3
20 A 2 WIRE
3 WIRE
4 WIRE
OTHER VOLTAGES AVAILABLE:
Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
DANGER
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
DANGER
AVERTISSEMENT: Directives
pour la prise de courant électrique Cet
appareil est muni d'une fi che à trios
branches (prise de Courant) afi n de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fi che.
NOTE: Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
When required, recommended ground
fault for Combitherm ovens is an
appropriately sized breaker with
built-in 30mA ground fault protection.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.