INSTALLATION
SITE INSTALLATION
INSTALLATION CODES & STANDARDS
The following codes and standards are required for
installation of this oven:
AIR SUPPLY, ELECTRICAL CONNECTIONS,
WATER CONNECTIONS, AND WASTE WATER
DISCHARGE.
Installation must comply with local codes required
for gas appliances. In the absence of local codes,
installation must comply with the National Fuel
Gas Code, ANSI Z223.1 (latest edition). In Canada,
the appropriate code is the Natural Gas Installation
Code, CAN/CGA-B149.1 or the Propane Installation
Code, CAN/CGA-B. Adherence to code by a
qualified installer is essential for the following: Gas
Plumbing, Gas Appliance Installation, Commercial
Cooking Ventilation, Water and Plumbing, and
OSHA Regulations.
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
DANGER
AVERTISSEMENT : UNE INSTALLATION,
UN AJUSTEMENT, UNE ALTÉRATION,
UN SERVICE OU UN ENTRETIEN NON
CONFORME AUX NORMES PEUT CAUSER
DES DOMMAGES À LA PROPRIÉTÉ, DES
BLESSURES OU LA MORT.
LIRE ATTENTIVEMENT LES DIRECTIVES
D’OPÉRATION ET D’ENTRETIEN
AVANT DE FAIRE L’INSTALLATION, OU
L’ENTRETIEN DE CET ÉQUIPEMENT.
VENTILATION REQUIREMENTS
A steam ventilation hood is mandatory for the
operation of the oven. The ventilation hood must
be installed in accordance with local building codes
for the steam exhaust and must protrude 12-inches
to 20-inches (300 to 500mm) over the front side
of the oven. A grease filter must be located in the
protruding area of the hood. Grease filters should
be thoroughly cleaned on a regular basis following
manufacturer’s instruction. Ventilation hoods must
ensure an adequate amount of incoming air during
operation and must be operated whenever the
combination oven/steamer is used in order to avoid
the accumulation of condensation in the hood area.
See the section titled Gas Exhaust.