Alto-Shaam ASC-4G Convection Oven User Manual


 
MN-28664 • Rev 2 (06/13) • ASC-4G Gas Convection Oven - Manual Control • 8
INSTALLATION
This appliance is equipped with a three-prong
grounding plug. For your protection against shock
hazard this appliance should be plugged directly into
a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the “off” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by
a licensed electrician in accordance with applicable
local electrical codes.
ELECTRICAL CONNECTION
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS
120 1 60 7.5
9' (2743mm) cord with plug included: NEMA 5-15P