MN-28664 • Rev 2 (06/13) • ASC-4G Gas Convection Oven - Manual Control • 4
INSTALLATION
The oven must be mounted on the factory equipped
oven legs or on an optional oven stand. Installation
on a solid or concrete base that in any way restricts
air flow may void the warranty.
All clearances for a proper ventilation air supply
must be maintained to minimize fire hazard. Do
not locate the oven immediately adjacent to any
other heat-generating appliance.
A number of adjustments are associated with
initial installation and start-up. Adjustments
must be conducted by a qualified service
technician. Installation and start-up adjustments
are the responsibility of the dealer or user.
These adjustments include but are not limited to
thermostat calibration, door adjustment, leveling,
and gas pressure verification. The Platinum series
oven burners are factory-adjusted with fixed air
openings and require no field adjustment.
LEVELING
The oven should be
leveled before the gas
supply is connected. Level the oven from
side-to-side and front-to-back with the use of a
spirit level. For ovens installed on a mobile stand,
it is important that the floor surface be level due to
the probability of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the floor has not
shifted or the oven moved.
NOTE: Failure to properly level this oven can
cause improper function as a result
of erratic burner combustion and will
result in the uneven baking of products
consisting of semi-liquid batter.
INSTALLATION REQUIREMENTS
WARNING
Inadequate ventilation, or failure to
ensure an adequate supply of fresh
air will result in a high ambient
temperature at the rear of the
appliance. An excessive ambient
temperature can cause the thermal-
overload protection device on the
blower motor to trip resulting in
severe damage to the blower motor.
30-5/8" (778mm)
44-1/2" (1130mm)
58-1/2" (1486mm)
31-15/16" (810mm)
38" (965mm)
25-11/16" (652mm)
3-5/16" (84,4mm)
29-1/8" (740mm)
1/2" GAS INLET
3-5/32" (80mm)
6-15/16" (176mm)
9-15/16" (252mm)
LINE CORD ENTRANCE
31-1/16" (789mm)
4" (102mm)
1/2" GAS INLET
EXHAUST
VENT
CAVITY WIDTH
123°
129°
26-1/2" (673mm)
54-5/8" (1387mm)
3-11/16" (93mm)
LINE CORD ENTRANCE
12-15/16"
(329mm)
CORD LENGTH
9' (2,743mm)
MINIMUM 6 INCH
CLEARANCES FROM
COMBUSTIBLES AND
NON-COMBUSTIBLES
Ne pas installer à
une distance inférirure
à celle indiquée
ci-dessous d'une paroi
en matiére combustible:
Côtés 6 pouches,
Arriére 6 pouches
FOR USE ONLY ON
NON-COMBUSTIBLE
FLOORS.
Doit être utilisé
seulement sur des
planchers non
inflammables.
INTENDED FOR
OTHER THAN
HOUSEHOLD USE.
Destiné à un usage
autre que domestique.
3107173
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
PRODUCT\PAN CAPACITY
72 lb (33 kg) maximum • 45 qts (43 liters)
Twelve (12): 18" x 26" x 1" full-size sheet pans
6 chrome plated wire shelves with 2 removable side racks
and 12 shelf positions spaced at 1-3/4" (43mm)
MODEL ASC-4G
manual control