MN-28907 (Rev 0) • AR-7EVH Electric Rotisserie with Ventless Hood Operation & Care Manual • 5
INSTALLATION
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National Electrical
Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the “off” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by
a licensed electrician in accordance with applicable
local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the “on
position. The main power switch can be left “on
for daily use, but should be turned “off” when
cleaning or performing maintenance or repairs to
the rotisserie.
ELECTRICAL CONNECTION
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
“WARNING” RISK OF FIRE!
Use a UL Listed grounding type plug rated 250 Volts,
50 Amperes, 1 Phase, 3 wire for single phase units and
250 V, 50 A, 3 Phase, 4 wire for three phase units. Plug
to be selected and installed only by qualified service
personnel. Individual conductors are marked L1, L2, L3
when applicable, N when applicable, and G.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS KW
208 1 60 40.0 8.3
BARE END
NO PLUG
240 1 60 38.0 8.8
208 3 60 33.0/ph 8.3
BARE END
NO PLUG
240 3 60 32.0/ph 8.8
380-415
(AGCY)
3 50/60 24.0/ph 8.8
NO CORD
NO PLUG
380 3 50/60 22.0/ph 7.4
415 3 50/60 24.0/ph 8.8
NOTE: Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
Power Cord Connection: The side connection
is recommended for all applications. If a bottom
connection is necessary for counter top units, user
will need to provide a cutout in the countertop to
allow the cord to hang freely without crimping.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with plug,
an all-pole country approved disconnection device which
has a contact separation of at least 3mm in all poles must
be incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the green/yellow
conductor shall be connected to the terminal which is
marked with the ground symbol. If a plug is used, the
socket outlet must be easily accessible. If the power
cord needs replacement, use a similar one obtained
from the distributor.
Wire diagrams are located in the inside access panel of the unit.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.