SE-4200/4400 WATER FILTRATION SYSTEM
5
P/N 1010852 Rev. C 04/06
SPECIFICATIONS
Electrical Ratings
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other appli-
cable codes.
WARNING
ELECTRICAL SHOCK HAZARD. FAILURE TO
FOLLOW THE INSTRUCTIONS IN THIS MANUAL
COULD RESULT IN SERIOUS INJURY OR DEATH.
• Electrical ground is required on this appliance.
• Do not modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
• Do not use an extension cord with this appli-
ance.
• Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
Model &
Mfg. #
Voltage Watts Amps Hertz
SE-4200
9700501 &
9700505
120 150 1.25 50/60
SE-4400
9700508 &
9700512
230 150 .75 50/60
Operating Specifications
Operating Weight
Unit A
Width
(inches)
B
Depth
(inches)
C
Height
(inches
Operating
Weight
(w/water)
(lbs)
SE-4200 12 14 49.75 93
SE-4400 12 14 69.75 127
NOTE: See Dimensions drawing on the next page.
Max. Operating Pressure 7 bar (100 psi)
Max. Operating Temp. 40°C (104°F)
pH Range 1-13
Trans Membrane Pressure 0.5-3 Bar (7.25-43.5 psi)
MWCO 100 kd
Letter
Code*
Description Configuration
C Commercial Cord
Harmonized Cord
(H)C** CEE 7/7, 16
Amp., 250 VAC
(Assembly Only).
(C)F*** 5-15P, 15 Amp.,
120 VAC., Non –
Locking (Assembly
Only).
WHT
BLK
GRN
* Used in Model Designation
** Indicates the Plug comes with a Harmonized Cord
*** Indicates the Plug comes with a Commercial Cord
Electrical Cord & Plug Configurations