CAUTION
Water Pressure must not exceed 7 bar (100 psi).
To reduce water pressure, install a water pressure
regulator and set water pressure to suit applica-
tion. Note that the trans membrane pressure
must be .5 - 3 bar (7.25 - 43.5 psi).
CAUTION
This equipment is to be installed to comply with
the basic plumbing code of the Building Officials
and Code Administrators, INC. (BOCA) and the
Food Service Sanitation Manual of the Food and
Drug Administration (FDA).
Unpacking
The carton should contain the filtration system and an
information packet.
SE-4200 or SE-4400
Information Packet
1. Remove unit and all packing materials from ship-
ping carton.
2. Remove all packing materials and protective cov-
erings from the unit.
2. Remove the information packet. To prevent delay
in obtaining warranty coverage, fill out and mail
the warranty card.
NOTE: If any parts are missing or damaged, con-
tact Antunes Filtration Technologies IMMEDIATELY
at 1-800-253-2991 (toll free in the U.S.) or 630-784-
1000.
Equipment Setup
GENERAL
When placing the unit into service, pay attention to the
following guidelines.
Make sure power to the unit is off.
Do not immerse the power cord or plug in water.
Keep power cord away from heated surfaces.
ELECTRICAL
Ensure that the line voltage corresponds to the stated
voltage on the units specification label. Make sure
that the plug on the power cord from the system and
the outlet match. For proper operation of the system,
and to ensure the highest quality of water from the sys-
tem, make sure that the system is not connected to a
switched electrical outlet.
An ABC-type fuse (6 Amp, 250 VAC) is located inside
the control box.
PLUMBING
NOTE: This unit is designed to use tap water not to
exceed 104º F (40º C).
The SE Series uses the following connections:
Water Inlet (Feed Water) 3/4” NPT
Permeate (Product Water) 3/4” NPT
Drain 3/4” NPT
INSTALLATION
When making a plumbing connection to the system,
remember to use a back-up wrench on the support
plumbing. Always use a good quality and approved
pipe sealant or Teflon tape on pipe threads.
Be careful not to get the pipe sealant inside the pipe
when making the connections. Do not over tighten the
connections.
It is recommended that plastic fittings be used when
connecting to the plastic connections of the system.
This will reduce the possibility of cracking the connec-
tions due to over tightening. If soldered plumbing is
used, do not apply heat to, or near, the filtration system.
The use of union (O-ring seal) connections is highly
recommended for ease of installation and future servic-
ing.
Suggested Tools and Supplies for
Installation
The following tools and supplies are suggested to make
the installation easier:
Screwdriver
Drill with bits
Strap wrench
(up to 6” diameter)
Tape measure
Two gallon bucket
Fresh 5 1/4% liq-
uid chlorine bleach
(such as Clorox®)
Adjustable wrenches
Pipe wrenches
Level
Pipe dope or Teflon