1InRow RP Technical Data Manual
Overview
The modular, row-based computer
room cooling system offers efficient,
predictable, and economical cooling
for a variety of spaces.
Critical environmental requirements
now reach far beyond the confines of
the traditional data center or
computer room to encompass a larger
suite of applications, referred to as
technology rooms. Critical
environment applications include:
• Computer rooms
• Telecommunication facilities
• Clean rooms
• Power equipment
• Medical equipment rooms
• LAN/WAN environments
A worldwide network of APC
representatives is fully qualified to
provide engineering, sales,
installation, and service for our
products.
APC warrants all parts for 18 months
from shipment and 12 months from
startup. Extended warranties are
available.
Capacity
The InRow RP chilled water
configuration is available in one size
with a capacity that is up to 60 kW
based on the particular application of
the unit. The InRow RP air-cooled
configuration is available in one size
with a capacity that is up to 37 kW.
Room Air Distribution
Row-based systems are placed in line
with rack enclosures. At least one
system is used per hot aisle. Air is
drawn in through the rear of the
system, cooled, and discharged into
the cold aisle, thereby neutralizing
the sensible heating effects of the
data processing equipment.The
InRow RP delivers high volumes of
airflow to eliminate hot spots in
densely populated environments.
Configuration
• Chilled Water
• Air-cooled
Compliance Approval
• UL Listed
• VDE
• CE
• C-tick
• C-UL Listed
Chilled Water Standard
Features
• Insulated cabinet
• Backward inclined impeller
• Variable speed fans (3)
• Shutdown input/alarm output
• Chilled water flow meter
• 2-way/3-way floating point valve
• Humidifier
• Counter flow cooling coil
• Electric reheat
• Pleated 100 mm (4 in) filter
• NPT to BSPT pipe adapters
• Top or bottom piping
• Condensate management with dual
position float
• Network management card
• Baying Kit InRow RP to
NetShelter® SX rack
• Remote temperature sensor (3)
• Microprocessor controller
• Automatic transfer switch
Air-cooled Standard
Features
• Insulated cabinet
• Backward inclined impeller
• Variable speed fans (2)
• Shutdown input/alarm output
• Humidifier
• Cross circuited cooling coil
• Electric reheat
• Pleated 100 mm (4 in) filter
• Pipe adapters
• Top or bottom piping
• Condensate management with dual
position float
• Network management card
• Baying kit InRow RP to
NetShelter
®
SX rack
• Remote temperature sensor (3)
• Microprocessor controller
• Variable speed reciprocating
compressor using VFD control
• Liquid line solenoid valve
• Pressure equalization solenoid
Accessories
• Cable leak detector
• Baying kit InRow RP to NetShelter
VX rack
• NetShelter SX 42U to 48U height
adapters
• NetShelter VX 42U height adapters
• Bridge trough power cable shield
• Data cable bridge partition
• Flex hose piping kits