Beko CCB 5140 XA Ventilation Hood User Manual


 
7 / 11 ENHood / User Manual
A
Caution:
Preparation of the installation place
and electric wiring is the responsibi-
lity of the customer.
C
Note:
The height between the lower surfa-
ce of the hood and upper surface of
the oven/hob should not be less than
65 cm.
Assembly and electrical connections
must be carried out by specialized
personnel.
Remove the protective film (if any) on
the hood and flue surface after the
installation.
3.1.Electrical connection
The hood shall be connected to an ungrounded
mains outlet that is protected by a fuse with pro-
per capacity.
Your appliance is manufactured with a supply cord
with 2 threads, and it should be connected to the
mains supply with an electric switch that has a
minimum clearance of 3 mm between the 2-pole
terminals.
A
Caution:
Have a qualified electrician perform
the electric connection.
C
Note:
Connection shall comply with natio-
nal regulations.
The power outlet shall be reached
easily after installation.
Voltage and fuse protection al-
lowed is specified in “Technical
Specifications.”
Specified voltage shall be equivalent
with your mains voltage.
Do not connect the appliance with
extension cords or multiple outlets.
3 Installation
C
Note:
An omnipolar switch with a minimum
opening of 3mm between contacts,
in line with the electrical load and
local standards, must be placed
between the appliance and the mains
network in the case of direct connec-
tion to the mains network.
Once the electrical connection has
been completed, check that the top
illumination, motor and speeds work
properly.
A
Caution:
Any damaged power cord must be
replaced by a qualified electrician.
Do not operate the appliance before
it is repaired! Risk of electric shock!
3.2 Preparation
Make a rectangular opening in the base of the
overhead cupboard or hood, leaving a minimum
of 13 mm from the outer edges according to the
dimensions indicated in the table.
Drill a hole into the upper side of the cupboard in
accordance with the dimensions of the duct used
for both the extraction and recirculation.
Dismantle the ducting support by pulling the two
knobs (A) (fig. 1) simultaneously:
Figure 1