Beko CWB 9601 X Ventilation Hood User Manual


 
7 / 13 EN
3 Set-up
3.1 Preparation
Information required for the preparation of the
installation place for your hood is given below.
(Dimensions are given in mm)
A
WARNING: The height between the lower
surface of the hood and upper surface of
the stove/oven should not be less than
65 cm.
3.2 Power connection
This appliance is manufactured with a supply
cord with 3 threads, and it should be connected
to the mains supply with an electric switch that
has a minimum clearance of 3 mm between the
3-pole terminals. Have a qualified electrician
perform the electric connection.
Install your unit so that you can reach the elec-
tric connection (plug, outlet) easily after instal-
lation.
3.3 Installation of the Hood
Please consult the nearest Arçelik Authorized
Service for the installation of the hood.
Preparation of the installation place and electric
wiring is the responsibility of the customer.
A
WARNING: Remove the protective film (if
any) on the hood and flue surface after
the installation.
Perform the transport operations with the origi-
nal package of the unit observing the markings
on the package. Protect your unit against factors
that may harm the package and the unit (humid-
ity, water, impact etc.).
Hood should be placed as aligned by the central
axis of the cooking unit. The distance between
the cooking unit and oil filters of the hood should
be at least 65 cm.
Perform the following steps for the installation of
the hood.
Hood / User Manual