ELECTRICALCONNECTION
The appliance shall be connected toa single
phase electric line rated at 120/208Vac or
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:2400Wattor12.0Amax.
‐120/240Vac:3100Wattor13.5Amax.
Heatingelementspowerrating:
‐Ovenbakeelement=1800Watt
‐Ovencircular
element=3000Watt
‐Ovendoublebroilelement=1200+1800Watt
Installa suitableelectricpowersupplyreceptacle
connectiontypeNEMA1450Rabletosupporta
loadofatleast16A(perline)accordingtolocal
coderequirements.Forfourorthreewirespower
supplyconnectionsystemsee
diagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Checkyourlocalcode forwhichoftheoptions
belowshould be usedin grounding the
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incomingBLACKelectricalsupplywire(L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRALreceptacleter minal to
the incoming NEUTRAL (WHITE) electrical
supplywire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supplywire
OPTION 2 - THREE-Wires connection:
‐ Connect the L1 receptacle terminal to the
incomingBLACKelectricalsupplywire(L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacleterminalto theincomingNEUTRAL
(WHITE)electricalsupplywire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of
PERSONAL INJURY.
Theappliance isequippedat thefactory withan
electric supplycord set4 wirestype withring
terminals(L1,L2, N,Ground)suitablefor range
useUL/CSAlistedtypeSRDT/DRT2x6AWG(L1,
L2)+2x8AWG(N, G) rated300V, 40 or 50Awith
fusedplug typeNEMA 1450P;cablelength 1,5
m.;incasethesupplycordsetmustbereplaced,
itshallbereplacedwithanidenticalsethaving
the same technical specsand followingcarefully
theinstructionsanddiagramsbelow:
1) Disconnect appliance from electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccessto
backenclosurepanel
3) Remove back enclosure panel by removing
the6screwsasshownbelow