4) Loosestrainreliefbyunscrewingthetwo
strainrelief'sscrewsasindiagram.
5) Removedamaged supplycordset bytaking
off the 4 electrical connection screws (block
L1,N,L2andGroundscrew,seediagram)
6) Insert thenew supplycord set in thestrain
relief and lock it with two strain relief's
screwsinsuitableposition.
7) Fixwellthering
terminalsG,L1,N,L2ofthe
new supply cord set asshown in diagram
withits4screws
8) Reinstall the back enclosure panel with 6
screws
9) Slide the appliance back into its proper
location
10) Reconnect the appliance to the electrical
power.
ELECTRICALGROUNDING
Thisapplianceisequippedwithafourprongplug
for your protection against shock hazard and
should be plugged directly into a properly
grounded receptacle. Donot cut orremove the
groundingprongfromthisplug.