BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the abs ence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codesor,inthe absenceoflocalcodes, withthe
National
ElectricalCode,ANSI/NFPA70.
Iflocal codespermit, aflexiblemetalappliance
connection withthe newAGA orCGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gassupply line.Do notbend ordamage the
flexibleconnectorwhenmovingthe
appliance.
Thisappliance mustbe usedwith thepressure
regulator pr ovided. The regulator shall be
properlyinstalledinordertobeaccessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas ½”
female
pipe thread. The appropriate fitting must be
determinedbasedonthesizeofyourgassupply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduring anypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholes inthewallandfloor, back
andundertheapplianceshallbesealedbefore
installationoftheappliance.
Amanualvalveshallbeinstalledinanaccessible
locationinthegas
lineexternalto theappliance
forthepurposeofturningonorshutting offgas
totheappliance
WARNING:This applianceshallnot beinstalled
with a ventilation system that air downward
towardthera nge/rangetop/cooktop;thistypeof
ventilation system may cause ignition and
combustion problem with the gas cooking
appliance
resulting in a personal injury or
unintendedoperation.
WARNING: an air curtain or other overhead
range/rangetop/cooktop hood, which operates
by blowing a downward airflow onto a
range/rangetop/cooktop, shall not be
used/installed in conjunction with this gas
range/rangetop/cooktop.
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliance
whileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used withthe appliance; in eachcase itshall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectotherventedappliances;in
eachcase itshallbe installedinconformitywith
the
appropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural gas. For use with propane LP gas
please follow the conversion procedure
describedonpg.17. Astepbystepconversion
procedureisalsoincludedwitheachsetofLP gas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
watercolumn(5kPa).
Theminimumgassupplypressureforchecking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
the appliance
(this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand11”w.c.(2.75kPa
forLPGas).