Blodgett SC-10E Convection Oven User Manual


 
6
ELECTRICAL CONNECTION
WARNING: Electrical grounding connections must comply with
applicable portions of the National Electrical code and/or other local
electric codes.
WARNING: Disconnect the power supply to the appliance before
cleaning or servicing.
Make electrical connection through the 1-1/8" (29 mm) diameter hole provided using 3/4"
(19mm) trade size conduit. Refer to the wiring diagram located inside the right side
panel. Use 90°C minimum insulated wire.
PLUMBING CONNECTIONS
WARNING: Plumbing connections must comply with applicable
sanitary, safety, and plumbing codes.
The water supply inlets are provided with 3/8" (10 mm) compression fittings for 3/8" O.D.
copper tubing. The water supply line pressure should be 25 - 50 psi (170 - 345 kPa) for
each line. The water supply to the generator tank is separate from the water supply to
the cooling system where steam is condensed before entering the drain line.
Install line strainers (not provided). A manual shutoff valve for each supply line must be
provided convenient to the steamer.
We recommend treated water feeding the boiler inlet supply, and untreated water
feeding the cooling system inlet. Hook-ups are labeled on the back of the steamer.