OPTIONAL OIL WAND
RETURN FRYER TO NORMAL OPERATION
1. After washing down frypot, turn DRAIN VALVE HANDLE
horizontal to close the frypot drain.
IMPORTANT: Drain handle must be fully closed in order to
activate HEATER SAFETY SWITCH. Drain handle must be
horizontal before for fryer heating element can be energized.
2. At conclusion of use, press FRYER-OFF-FILTER switch to
OFF position, disconnect wand from fryer fitting and return
handle of the 3-WAY VALVE to the vertical position.
3. Drain any remaining oil in wand by pointing discharge nozzle
of wand down into frypot or disposal container.
4. Be sure 3-WAY VALVE HANDLE is vertical.
Press FRYER-OFF-FILTER switch to FILTER position.
When all oil has been returned to frypot, press FRYER-OFF-
FILTER switch to FRYER position to resume operation, or to
OFF position to shut down.
DANGER:
BURN HAZARD
Contact with hot oil will cause
severe burns.
Always wear protective clothing
and heat resistant gloves when
operating the fryer.
CAUTION: BURN
HAZARD
Overflow of hot oil may cause
burns. DO NOT fill fryer beyond
MAX OIL line on frypot.
IMPORTANT:
When refilling the frypot, be
sure the 3-way valve handle is
vertical, and the drain valve
handle is horizontal before
pressing FRYER-OFF-FILTER
switch to the FILTER position.
OPERATION - OPTIONAL FILTER WAND (continued)
21
FRYER
OFF
FILTER
DRAIN "
(HANDLE HORIZONTAL)
CLOSED"
3-WAY VALVE
TO “ ”
(HANDLE
VERTICAL)
FRYPOT
HEATER SAFETY SWITCH
(" " WHEN DRAIN
HANDLE FULLY CLOSED)
SAFE
363 30007 OpManual for WFAE-55F/FS Electric Fryer