Breville the Dual Boiler Espresso Maker User Manual


 
22 23
PAge heAder..... PAge heAder.....
OPERATING YOUR BREVILLE PRODUCT
Temperature Unit - ˚C/˚F (SEt)
Set units to metric or imperial. While ‘SEt’ is
displayed on the LCD, press MENU button.
Press UP or DOWN arrow to the desired
unit. Press MENU button to set. Machine
will beep to confirm selection.
Steam Temperature (StEA)
Adjust the steam boiler temperature,
which in turn controls steam pressure.
Lower steam temperature to texture smaller
volumes of milk or to have more control.
Increase steam temperature to texture larger
volumes of milk.
While ‘StEA’ is displayed on the LCD, press
MENU button. Press UP or DOWN arrow
to the desired temperature. Press MENU
button to set. Machine will beep to
confirm selection.
Disable AUTO OFF (A OF)
Use this function to disable the Auto Off
feature. While ‘A OF’ is displayed on the
LCD, press MENU button. Press UP or
DOWN arrow to select off or on. Press
MENU button to set. Machine will beep
to confirm selection.
Machine Audio (Snd)
Adjust the audible alerts. While ‘Snd’ is
displayed on the LCD, press MENU button.
Press UP or DOWN arrow to off (OFF), low
(LO) or high (HI). Press MENU button to
set. Depending on the selected setting, the
machine may beep to confirm selection.
OPERATING YOUR BREVILLE PRODUCT
Volumetric Control (vOL)
Select between volume based (FLo) or
time based (SEc) method for espresso dose
measurement. While ‘vOL’ is displayed on
the LCD, press MENU button. Press UP or
DOWN arrow to the desired method. Press
MENU button to set. Machine will beep to
confirm selection.
PRE-INFUSION PROGRAMMING
With the machine on and in STANDBY
mode, press UP and DOWN arrow together
to enter Pre-Infusion Programming mode.
Press MENU button to move between
Pre-Infusion Duration (Pd) and Pre-Infusion
Power (PP).
Pre-Infusion Duration (Pd)
The LCD will display the current
Pre-Infusion Duration.
Press UP or DOWN arrow to vary time.
We recommend a range between 5–15 secs
as being optimum. Press MENU button to
access Pre-Infusion Power, or press EXIT
button to set.
Pre-Infusion Power (PP)
The LCD will display current
Pre-Infusion Power.
Press UP or DOWN arrow to vary power.
We recommend a range between 50–65 as
being optimum. Press EXIT button to set.
ALERTS
STEAM LEVER beeps during heat-up
The machine will beep 3 times and not
reach operating temperature (STANDBY
mode) if the STEAM LEVER is in the OPEN
position. Move the STEAM LEVER to the
CLOSED position.
HOT WATER LED flashing during heat-up
The machine will not reach operating
temperature (STANDBY mode) if the HOT
WATER dial is in the OPEN position. The
HOT WATER LED will flash. Move the HOT
WATER dial to the CLOSED position.
HOT WATER LED flashing
To ensure water is dispensed at the correct
temperature, hot water will cease to
dispense after approx. 30 seconds and the
HOT WATER LED will flash. Move the
HOT WATER dial to the CLOSED position.