Bunn 14 Coffee Grinder User Manual


 
13
PROGRAMMING THE DISPENSER (Cont.)
GLOSSARY
Put "NORMAL/PROGRAM/RINSE" switch into "PROGRAM" position to access program menus.
Adjust tank temperature
(190° F maximum)
Adjust minimum tank ready temper-
ature for lockout (185° maximum)
Adjust hopper motor speed for hopper 1.
## indicates hopper rpm
TANK TEMP ###°
(-) EXIT (+)
READY TEMP ###°
(-) EXIT (+)
DRINK STRENGTH 1
(-) ## (+)
###° CAL ###°
(-) tank temp (+)
235 REFILL 155
(-) EXIT (+)
Calibrate temperature probe
Set refill probe threshold
AUGER DELAY
(-) .## sec (+)
Set delay start of hopper after dilution
valve opens in station selected
DISPENSE LOCKOUT
NO EXIT YES
RINSE ALARM ?
NO EXIT YES
SET PASSWORD ?
NO EXIT YES
Enables lockout of dispensing if below
minimum water temperature
Enables rinse alarm
Allows password to be set to
prevent altering setup functions
AUDIBLE ALARM?
NO EXIT YES
ENTER ASSET # ?
Turns on audio alarm
Enter asset number of machine
Enables service number to be
displayed on door display
TEST SWITCHES ?
Use Switch To Test
TEST HEATER ?
EXIT YES
TEST REFILL ?
EXIT YES
TEST AUGERS ?
DISPENSE TO TEST
TEST WHIPPERS ?
DISPENSE TO TEST
Allows testing of dispense
switches
Allows manually activating
tank heater
Allows manually activating
refill valve
Allows manually activating
hopper motors
Allows manually activating
whipper motors
ENABLE SERVICE #
NO EXIT YES
TEST DISP VALVES
DISPENSE TO TEST
Allows manually activating
dispense valves
If password is set, requires entering
password to access remainder of menus
ENTER PASSWORD
(-) 0 (+)
Runs auger motor (1 thru 6) at
programmed speed for 10 seconds
to check throw rate
TEST POWDER #?
PRESS DISPENSE
Opens water dispense valve (1 thru 4)
for 20 seconds to test flow rate
TEST WATER #?
PRESS DISPENSE
DILUTION DELAY
(-) #.## sec (+)
Set delay start of dilution water valve
for single product beverages
NO EXIT YES
### POWDER 155
(-) EXIT (+)
Set low powder detect threshold
SET TO EMPTY
(-) 100 REVS (+)
Set number of Auger turns after low
level detected until hopper empty
Enables service agent telephone num-
ber to be displayed on door display
ENABLE SERVICE #
NO EXIT YES
TEST HOT WATER ?
EXIT YES
Allows manually activating hot
water valve
45304.1 090611