Bunn 34766.0000S Coffeemaker User Manual


 
12
Rinse Procedure:
1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.
2. Place a 2 Liter (1/2 Gal) container under the Left dispense tip.
3. Activate the Left dispenser until water flow stops automatically, approximately 20 sec.
4. Repeat Steps 2 & 3 for the Right dispense tip.
The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.
5. Open the cabinet door and select Normal on the Function Selector switch – close the door.
BIB Empty Lockout Feature
The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first
calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning). Then enable the BIB Empty
Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser). The dispenser will now
Lockout dispensing and flash the Right or Left “REFILL LED” corresponding to the empty BIB. Once the BIB has
been replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) and then dispense mixed
product until the “REFILL LED” goes out. NOTE: If the dispenser fails to clear the BIB Empty Lockout, repeat the
Priming operation a second time to insure the concentrate is flowing properly.
Brew Temperature Lockout Feature
The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To
enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the
Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser.
34766 042304
1 5