Bunn 34766.0000S Coffeemaker User Manual


 
27
Screen Displayed Possible Cause Troubleshooting Procedures
Dispenser Diagnostics-LCD Display
Troubleshooting (Continued)
34766 011604
LF TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
RT TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
LF TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
RT TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
LEFT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
RIGHT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
1. The Tube Size selected for the Left
Hand Dispenser is too small for the
application.
2. The Ratio selected for the Left Hand
Dispenser is not correct for the
application.
1. The Tube Size selected for the Right
Hand Dispenser is too small for the
application.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the
application.
1. The Tube Size selected for the Left
Hand Dispenser is too large for the
application.
2. The Ratio selected for the Left Hand
Dispenser is not correct for the
application.
1. The Tube Size selected for the Right
Hand Dispenser is too large for the
application.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the
application.
1. Concentrate BIB is Empty.
2. BIB Not properly connected.
3. Tubing kinked or blocked.
4. Empty BIB Warning set too high.
1. Concentrate BIB is Empty.
2. BIB Not properly connected.
3. Tubing kinked or blocked.
4. Empty BIB Warning set too high.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
Refer to recommended Dispense Ratio
on the product label.
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating
the Empty BIB Warning
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating
the Empty BIB Warning