Page 32
SPRAY OZ/M (DUAL BREWERS)
This function allows the operator to view or to enter
the actual flow rate coming out of the sprayhead. This
is NOT used to change the actual flow rate, but to tell
the internal controller how fast the water is flowing.
The unit of measure is ounces per minute (Oz/M).
Procedure to adjust the flow rate setting:
1. Press and hold upper right hidden switch until the
display reads UNITS. Release switch. Continue to
press and release switch until the display reads,
L SPRY OZ/M. The number represents what the
brewer thinks is the flow rate of the sprayhead in
ounces per minute.
2. If the actual flow rate of the sprayhead is known,
but is different than the number on the display,
use the (-) and (+) to enter the correct flow rate
in ounces per minute.
3. When finished, press and release DONE. This saves
the new setting and advances to R SPRY OZ/M.
When finished setting the right side, press and
release DONE to advance to next function screen,
L BYPS OZ/M. Another alternative is to press and
release either ON/OFF switch located on the front
switch panel to exit R SPRY OZ/M function and
return to the MAIN SCREEN.
SPRAY OZ/M (SINGLE BREWERS)
This function allows the operator to view or to enter
the actual flow rate coming out of the sprayhead. This
is NOT used to change the actual flow rate, but to tell
the internal controller how fast the water is flowing.
The unit of measure is ounces per minute. (Oz/M)
Procedure to adjust the flow rate setting:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
SPRAY OZ/M. The number represents what the
brewer thinks is the flow rate of the sprayhead
valve in ounces per minute.
2. If the actual flow rate of the sprayhead valve is
known, but is different than the number on the
display, use the (-) and (+) to enter the correct
flow rate in ounces per minute.
3. When finished, press and release DONE. This saves
the new setting and advances to the next function
screen, BYPASS OZ/M. Another alternative is to
press the ON/OFF switch located on the switch
panel to exit SPRAY OZ/M function and return to
the MAIN SCREEN.
SPRY OZ/M: XX.X
(-) DONE (+)
BYPS OZ/M: XX.X
(-) DONE (+)
R SPRY OZ/M: XX.X
(-) DONE (+)
L SPRY OZ/M: XX.X
(-) DONE (+)
L BYPS OZ/M: XX.X
(-) DONE (+)
PROGRAMMING FUNCTIONS - (cont.)
41343 080108