Bunn FCD-4 Beverage Dispenser User Manual


 
19
Dispense Fault List
“REFILL” indicator Beeper Fault
2 flashes 2 beeps Dispense station locked out.
3 flashes 3 beeps DISPENSE/RINSE sensing fault.
4 flashes 4 beeps DISPENSE/RINSE knob mis-positioned.
5 flashes 5 beeps Pump motor stalled/speed sensor inoperative.
All “REFILL” 3 beeps Dispenser locked out.
indicators flash
3 times
Dip Switch Function List
Dip Switch Controls Off On
1 “REFILL” indicator when “concentrate out” is detected. Inactive Active
2 Lockout dispense components when “concentrate out” is detected. Inactive Active (Note)
3 Number of positions that can dispense/rinse simultaneously. 3 2
4 Rinse timer Off On
5 Audio feedback during dispenses. On Off
6 Future use. None None
Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1
position.
Cooling Fault List
Fault Code “COOLING” DBC display Fault Fault
indicator (optional) Priority
8 8 flashes every fault 8 Bath water level low. 1
5 seconds (Also lights all “WATER” indicators)
7 7 flashes every fault 7 Bath temperature probe short circuit. 2
5 seconds
6 6 flashes every fault 6 Bath temperature probe open circuit. 3
5 seconds
5 5 flashes every fault 5 Cabinet temperature probe short circuit. 4
5 seconds
4 4 flashes every fault 4 Cabinet temperature probe open circuit. 5
5 seconds
3 3 flashes every fault 3 Cooling system failure 6
5 seconds (disables all dispense functions)
0 On steady Bath/cabinet Bath and cabinet temperatures excessive. 7
temperatures
2 2 flashes every Bath/cabinet Bath temperature excessive. 8
5 seconds temperatures
1 1 flash every Bath/cabinet Cabinet temperature excessive. 9
5 seconds temperatures