Bunn ITCB-DV Coffeemaker User Manual


 
Page 45
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
ENABLE ENERGYSAVR
This function allows the operator to enable the mode
function and set the idle time. Once the set idle time
has expired, the operator can choose to have the heat-
ers either turn off, or reduce the tank holding temp to
140° F (60° C).
Procedure to enable energy savings mode:
Range: 0.5 to 24.0 hrs. If enabled, default setting is
140°F tank temperature after 4.0 hrs. idle time.
1. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads ENABLE
ENERGYSAVR. The YES or NO will be flashing to
indicate the current selection.
2. Press and release the NO button to disable this
function, or:
3. Press and release the YES button to enable this
function (the heaters will either turn off or the tank
will hold at 140° F).
4. When finished, press and release DONE to save
the new setting and advance to the next function
screen.
5. If NO was selected, the display should now read
EnableFreshTimer. To exit programming and return
to the MAIN SCREEN, press and release the ON/OFF
pad.
6. If
YES was selected, the display should now read
X.X HRS -> IDLE. This screen allows the operator
to set the amount of time the brewer is not in use
before nap mode engages. Using (-) and (+), adjust
the idle time. When finished, press and release
DONE.
7. The display should now read AFTER IDLE TIME?
Once the set idle time has expired, the heaters can
either be shut off or held at a lower temperature of
140° F.
8. To have the machine shut off after the set idle time,
press and release OFF and then DONE to save the
settings. The display should read MACHINE OFF
AFTER X.X HRS, and then EnableFreshTimer.
9. To have the heaters hold at the lower 140° F
temperature, press and release 140° F and then
DONE to save the settings. The display should read
MACHINE AT 140° F AFTER X.X HRS, and then
EnableFreshTimer.
P2874
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
PRESSING DONE WILL
ADVANCE TO
ENABLEFRESHTIMER
ENABL ENERGYSAVR
NO DONE YES
ENABLEFRESHTIMER
NO YES
X.X HRS-> IDLE
(-) DONE (+)
AFTER IDLE TIME?
OFF DONE 140°
MACHINE OFF
AFTER X.X HRS
MACHINE AT 140°
AFTER X.X HRS
WITH NO FLASHING
PRESS DONE
WITH YES FLASHING
PRESS DONE
36748 070706
10. Once the idle time has expired, the display will
read either ENERGY SAVER...NO TEMPERATURE
or ENERGY SAVER...REDUCED TEMPERATURE,
depending on the settings. This screen will alternate
with PRESS ANY SWITCH TO RE-HEAT.