SERVICE (cont.)
DILUTION SOLENOID VALVE
FIG. 6 DILUTION SOLENOID VALVE
P1960.60
Location:
Viewing the brewer from the rear the dilution so-
lenoid is mounted on the right side of the solenoid
mounting bracket.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the white/blue and white wires from
the iced tea brew and dilution solenoid valves. With
the TEA/OFF/COFFEE switch in the "TEA" position
press the start switch.
3. With a voltmeter, check the voltage across the
white/blue and white wires. Connect the brewer
to the power source. The indication must be 120
volts ac.
4. Disconnect the brewer from the power supply.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
Wir-
ing Diagram
and check the wiring harness.
5. Remove both wires from the coil and check for
continuity across the coil terminals.
If continuity is present as described, reconnect the
white/blue and white wires and proceed to #6.
If continuity is not present as described, replace the
solenoid valve.
6. Check the solenoid valve for coil action. Connect
the brewer to the power source, place the TEA/
OFF/COFFEE switch in the "TEA" position and mo-
mentarily place the start switch in the lower posi-
tion and release. Listen carefully in the vicinity of
the solenoid valve for a clicking sound as the
coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water line before or after the solenoid valve,
or the solenoid valve may require inspection for wear,
and removal of waterborne particles.
If the sound is not heard as described, replace the
solenoid valve.
Removal and Replacement:
1. Remove all wires from the solenoid valves.
2. Turn off the water supply to the brewer.
3. Disconnect the water lines to and from the sole-
noid valves.
4. Remove the two #8-32 keps nuts holding the
mounting bracket to the trunk base.
5. Lift out the bracket.
6. Remove the two #10-32 slotted-head screws hold-
ing the solenoid valve to the mounting bracket.
7. Securely install the new solenoid valve to the
mounting bracket.
8. Attach the mounting bracket to the trunk base.
9. Securely fasten the water lines to and from the
solenoid valves.
10. Refer to Fig. 7 when reconnecting the wires.
FIG.7 SOLENOID VALVE TERMINALS
P1364
WHI to Main
Harness
WHI/RED
to Switch
WHI/BLU
to Switch
29466 082200
HOT COFFEE
BREW SOLENOID
ICED TEA BREW
SOLENOID
DILUTION