Bunn TWIN Coffeemaker User Manual


 
Page 14
Setting Pulse Brew – EASY Pulse Brew
Range: Minimum: will adjust to the minimum time
required to brew that batch using the set brew volumes
and flow rate for the sprayhead. Maximum – will adjust
depending on settings and will always be minimum time
+ 3 minutes. The brewer will automatically calculate
what the 1ST ON TIME, OFF TIMES, and LAST ON
TIME will be using THE INITIAL ON TIME, plus a 7
pulse routine.
22. Select EASY. With EASY flashing, select NEXT.
23. The display should now read BREW TIME: and a
batch light will be blinking. Select the batch size to
be modified.
24. Using (-) or (+), set the total brew time desired
including spray times and off times.
25. When finished, press the other batch size and repeat
step # 24.
26. When finished setting both batch sizes, press
DONE. The display will show the pulse settings to
accommodate the brew time entered. Press and
release each batch size to display the settings for
that batch. After a delay, the display should read 2
BATCHES DONE?
27. If both batch sizes are not correct, press NO to
return to the BREW TIME setup screen and repeat
steps 24-26.
Setting Pulse Brew/PreInfusion – MANUAL
28. Select MANUAL. With MANUAL flashing, select
NEXT.
29. The display should now read, 1
st
ON TIME and a
batch light will be blinking. Select the batch size to
be modified.
30. Using (-) or (+), adjust the 1
ST
ON TIME.
31. When finished, press the other batch size and repeat
step # 30.
NOTE: To disable pulse brew, set 1
ST
ON TIME to OFF.
Brewer will automatically pulse on tea recipes with a
brew volume greater than 86.0 oz.
32. When finished setting both batch sizes, press
DONE.
33. The display should now read OFF TIME. Adjust the
OFF TIME using (-) or (+).
INITIAL SPRAY
INITIAL SPRAY
ALTERNATES UNTIL
BREW CYCLE IS
COMPLETED
PRE-INFUSION
REMAINING ON
ON-
TIME
OFF-
TIME
OFF-TIME
OFF-
TIME
OFF-
TIME
ON-
TIME
ON-
TIME
9. If both batch sizes are correct, press YES. This will
advance to the DILUTE OZ (ITCB) or BYPASS %
(ICB)
10. Using (-) or (+), set the amount of dilution water for
that particular batch size to be dispensed through
the dilution nozzle into the tea dispenser (ITCB) or
% bypass water to be dispensed around the filter/
grounds (ICB).
11. When finished, press the other batch size and repeat
step #10.
12. When finished setting both batch sizes, press and
release DONE. The display should read 2 BATCHES
DONE?
13. If both batch sizes are not correct, select NO to
return to the BYPASS % function (ICB) or DILUTE
OZ function (ITCB) and repeat steps #10-12.
14. If both batch sizes are correct, press YES. This will
advance to the DILUTE DELY function (ITCB) or SET
PULSE BREW function (ICB) jump to step # 21.
15. (ITCB ONLY) Press and release YES. The display
should now read DILUTE DELY: and a batch light
will be blinking. Press and release the batch size
to be modified.
16. Using (-) or (+), set the time delay for the dilution
water to start for that particular batch size.
17. When finished, press the other batch size and repeat
step # 16.
18. When finished setting both batch sizes, press and
release DONE. The display should read 2 BATCHES
DONE?
19. If both batch sizes are not correct, press and release
NO to return to the DILUTE DELY setup screen and
repeat steps 16 - 18.
20. If both batch sizes are correct, press YES. The
display should now read SET PULSE BREW.
21. To set PULSE BREW press YES. The display should
now read SELECT METHOD. To set the EASY method,
continue to step # 22. To set by MANUAL method,
jump to step # 28.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
(cont.)
41581.2 091609