Bunn TWIN Coffeemaker User Manual


 
Page 19
PROGRAMMING THE BREWER (cont.)
* SET TEMP - ICB (MASTER TEMP - ITCB)
This function allows the operator to adjust the brew
water temperature in the tank. This also sets the hot
water faucet dispense temperature.
Procedure for setting the Set Temp
Range: 185° to 205° F (85° - 96° C)
1. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads SET TEMP.
2. Using (-) and (+), adjust the brew and faucet tem-
perature.
3. When finished, press and release DONE to save
the new setting and to advance to the next function
screen, READY DEGREE. Press ENABLE BREW ON/
OFF switch to exit programming and return to the
MAIN SCREEN.
* READY DEGREE
This function allows the operator to set the minimum
temperature allowable to start a brew cycle. The range
can be from 2° to 20° F below the set temperature. The
water must be at the READY temperature or higher
for the display to indicate READY TO BREW. If brew
lockout is enabled, the brewing process will not start
below this READY temperature.
Procedure to set ready temperature
Range: 2° to 20° F (2° to 10° C) below set temp
1. Press and hold the right hidden button until the dis-
play reads SET LANGUAGE. Press the right hidden
button until the display reads READY DEGREE.
2. Using (-) and (+), adjust the ready temperature.
3. When finished, select DONE to save the new setting
and to advance to the next screen, ENABLE ADS.
Press ENABLE BREW ON/OFF switch to exit.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
* ENABLE ADS
This function allows the operator to choose whether
or not to display an advertising message. An ad can be
saved to the brewer by either writing the ad using the
programming commands, or by entering the ad into
the brewer using an AD CARD. This message will be
displayed when the brewer is not in use.
Procedure to Enable/Disable Ads:
1. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right hid-
den button until the display reads ENABLE ADS. The
YES or NO will be flashing to indicate the current
selection.
2. Select NO to disable this function, or:
3. Select YES to enable this function.
4. When finished, select DONE to save the new setting
and advance to the next function screen.
5. If NO was selected, the display should now read
ENABLE SANITATION. To exit programming and
return to the MAIN SCREEN, press ENABLE BREW
ON/OFF switch.
6. If YES was selected, the display should now read
NEW AD?. This screen allows the operator to select
between using an ad card to read in a new ad, or
writing an ad through the control panel.
Procedure to WRITE an Ad:
NOTE: Writing and saving a new ad will erase any
previously saved ad in the brewer’s memory.
7. From the NEW AD? screen, select WRITE.
8. The display should now read 2 LINES 16 CHARS
AVAILABLE, and then SCROL THRU ALPHA, NEXT
-> NEXT LETTER, and then WRITE TOP LINE?. The
ad can be up to 32 characters long, 16 per line. The
ad will be written in two steps, first the top line,
then the bottom line.
9. To write the top line of a new ad, select YES. To skip
the top line and only write a bottom line, select NO
and proceed to step 13.
10. The display will now read A with a flashing cursor
below it. Press the SCROLL button to scroll through
the alphabet and available characters. When the de-
sired character is shown on the display, select NEXT
to move to the next character in the top line.
11. Repeat step 10 until the top line is complete.
41581.2 091609