MAINTENANCE
To Replace The Picture / Duratran GB w/ Metal Doors Only:
Lift up the two end tabs on top of door with a pointed object
or flat h
ead screwdriver.
Pull the entire picture frame out. Open up the two clear
pa
nels and replace picture.
Tuck clear plastic panel inside bracket at top.
Be sure to tuck clear panel
under bracket before sliding
frame ass'y inside door. The longer metal tab side goes
in the front.
To Replace The Fluorescent Bulb:
Remove the upper inside door panel. Turn the lamp and pull
it out of th
e lamp holder, then place the new lamp into the
lamp holder and turn it until it snaps into position.
To Replace The Starter:
Remove the upper inside door panel, turn the starter slightly
cou
nter-clockwise and take it out of the starter base. To
install the new starter, snap the starter into the starter base
and turn it slightly clockwise into position.
RECOMMENDED PREVENTIVE MAINTENANCE
1. Check All Chamber Mounts For Signs Of Wear
A. Product Running Down The Front Of The Unit.
B. Product Built Up On The Back Of Chamber Mount.
Remove Chamber Mount.
Clean And Re-Lubricat
e Motor Shaft
Using Food Grade Lubricant Only
Replace With New Chamber Mount.
2. Clean Out Vent Motor, Trough And Tubing.
Lift up black tabs, remove Trough Drawer,
Clean, and replace Trough Drawer.
Remove Hose Assembly From The Motor.
Clean Out And Replace.
3) Check All Dispense Valves For Lime Build-Up.
Drain The Water Tank To Just Below The Level Of The
D
ispense Valves.
Remove The Valves And Clean.
( You Can Take These Valves Apart By Hand As Shown).
Replace The Assembly As Needed (L467A).
Replace The Valve Into The Tank And Refill tank.
BULB TYPE
F8T5/CW
LAMP HOLDER
STARTER TYPE FS-5
STARTER BASE
BALLAST
DURATRAN
DURATRAN
FRAME ASS'Y
WATER FLOW ADJUSTMENT