INSTALLATION OF THE LOGS &
LAVA ROCK MATERIAL
Refer to Fig. 37 for log identication during this procedure.
1. Remove the front glass/frame assembly.
2. Remove the logs from their packaging
The logs should be handled with care as
the material is fragile.
Keep the packaging material out of the reach of
children and dispose of the material in a safe
manner.
3. Fit the right rear log ((A23) in place on the rear log sup-
port. The holes in the underside of the log t over the two
pins on the right end of the support shelf.
4. Fit the left rear log (A22) in place. The log sits on the left
end of the support shelf.
5. Fit the right front log (A25) in place. The holes in the
underside of the log t over the pins on the log support
bracket over the burner housing.
6. Fit the left front log (A24) in place. The left end of this
log rest on the outer edge of the burner housing, the inner
top fork rest across the cutout in the left rear log (A23)
and the inner front fork rest on the front edge of the burner
housing.
7. Fit the top log (A26) in place with the hole in the under-
side of the log aligning with the knob on the top of the left
rear log (A22) and the front of the log laying across the
cutout in the right front log (A25).
FLAME & TEMPERATURE
ADJUSTMENT
RN/RP Models
For units equipped with ‘HI/LO’ valves the ame adjustment
is accomplished by rotating the ‘HI/LO’ adjustment knob
located near the centre of the gas control valve, Fig.38 & 39
FLAME CHARACTERISTICS
It is important to periodically perform a visual check of the
pilot and burner ames. Compare them to the pictorials illus-
trated below, Figs. 40& 41.
If the ame patterns appear abnormal contact a qualied ser-
vice provider for service and adjustment.
PSE Pilot
SIT Top Convertible Pilot
DVR33 Log Set (viewed from above)
A22
A23
A24
A25
A26
Fig. 37
Fig. 38
Fig. 39
Fig. 40
DVR33