LIGHTING INSTRUCTIONS
3. Open control access panel.
4. Push in gas control knob slightly and turn clock-
wise to "OFF". Do not force.
5. Close control access panel.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a ame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.
• If knob does not pop up when released, stop
and immediately call your service technician or gas
supplier.
• If after several tries, the pilot will not stay lit, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to "ON" position.
13. For RN/RP appliances turn the On/Off switch to
"ON" position or set thermostat to desired setting.
14. Turn on all electrical power to the replace.
1. STOP! Read the safety information above on this
page.
2. Turn off all electrical power to the replace.
3. For MN/MP/TN/TP appliances ONLY, go on to
Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to lowest
level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
6. Wait ve (5) minutes to clear out any gas. Then
smell for gas, including near the oor. If you smell
gas, STOP! Follow "B" in the safety information
above on this page. If you don't smell gas, go to
the next step.
7. Remove glass door before lighting pilot. (See Glass
Frame Removal in manual).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counter clockwise
to "PILOT".
neighbour's phone. Follow the gas supplier's
instructions.
•If you cannot reach your gas supplier, call the
Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualied service technician. Applying force or any
attempted repair may result in a re or explosion.
D. Do not use this replace if any part has been under
water. Immediately call a qualied service techni-
cian to inspect the replace and to replace any part
of the control system and any gas control which has
been under water.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
If you do not follow these instructions exactly, a re or explosion may
result causing property damage, personal injury or loss of life.
A. This replace has a pilot which must be lit manu-
ally.
When lighting the pilot follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the re-
place area for gas. Be sure to smell next to the
oor because some gas is heavier than air and will
settle on the oor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any replace.
•Do not touch any electric switch
•Do not use any phone in your building
•Immediately call your gas supplier from a
TO TURN OFF GAS TO FIREPLACE
LIGHTING AND OPERATING INSTRUCTIONS
1. Turn the On/Off switch to “OFF” position or set
the thermostat to lowest setting.
2. Turn off all electric power to the replace if
service is to be performed.
EURO SIT
SIT NOVA
HONEYWELL
O
F
F
O
F
F
P
I
L
O
T
O
N
PILOT
ON
OFF
3/8" - 1/2"