#8701/2 Electric Convection Oven - Manual Control Pg. 7.
The oven must be installed by a qualified
electrician. This appliance must be branch circuit
protected with proper ampacities, in accordance
with the wiring diagram located in this manual or
in the electrical compartment of the oven. The
oven must be properly grounded in accordance
with the National Electrical Code and applicable
local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “off” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven
model. For supply connections, locate the wire
size posted on the label located near the electric
terminal block behind the service panel or
elsewhere listed in this manual. Before
attempting the electrical connection, the rating
plate should be checked to ensure that the
electrical characteristics of the appliance and the
electrical supply characteristics agree.
Installation of the wiring must be made in
accordance with U.L. 197 Commercial Electric
Cooking Appliance Standards, Local and/or
National Electrical Code, ANSI /NFPA 70-1990.
Service line entry is made through the rear of the
oven for connection to the terminal block.
Remove the service panel on the right side of the
oven for access to the terminal block.
The oven is wired at the factory for either single
phase or three phase service as indicated on the
original purchase order. Input voltage and phase
must match the voltage and phase of the oven.
Visually check all electrical connections.
E L E C T R I C A L C O N N E C T I O N
I N S T A L L A T I O N
ELECTRICAL ACS-2E
VOLTAGE PHASE CYCLE/ HZ AWG AMPS kW
208 1 50/60 10 25.5 5.3
240 1 50/60 10 22.0 5.3
208 3 50/60 12 14.7 5.3
240 3 50/60 12 12.8 5.3
NO CORD AND PLUG
ELECTRICAL ASC-4E
VOLTAGE PHASE CYCLE/ HZ AWG AMPS kW
208 1 50/60 6 50.0 10.4
240 1 50/60 6 43.3 10.4
208 3 50/60 8 25.0 10.4
240 3 50/60 8 25.0 10.4
NO CORD AND PLUG