Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure)
and the adjustment conditions are compatible. The adjustment conditions for this appliance are
stated on the data badge which is fitted behind the bottom of the main oven door seal. This
appliance is not designed to be connected to a combustion products evacuation device. It must be
installed and connected in accordance with current installation regulations. particular attention
should be given to the relevant requirements regarding ventilation.
MODEL NUMBER: S120G
Category I
2H
(GB. IE)
These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and can not be used
on any other gas.
GAS SAFETY (INSTALLATION & USE) REGULATIONS
It is the law that all gas appliances are installed by competent persons in accordance with
the current edition of the above regulations. It is in your interest and that of safety to ensure
compliance with the law.
In the UK, CORGI registered installers work to safe standards of practice. The appliance
must also be installed in accordance with BS 6172:. Failure to install the appliance
correctly could invalidate the warranty liability claims and could lead to prosecution.
LOCATION
The appliance may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in
a room containing a bath or shower. The appliance must not be installed in a bed-sitting
room of less than 20m
3
.
PROVISION FOR VENTILATION
The room containing the appliance should have an air supply in accordance with
BS 5440: Part 2:
The room must have an opening window or equivalent; some rooms may also require a
permanent vent. If the room has a volume between 5 and 10m
3
, it will require an air vent
of 50cm
2
effective area unless it has a door which opens directly to outside. If the room has
a volume of less than 5m
3
, it will require permanent air vent of 100cm
2
effective area.
If there are other fuel burning appliances in the same room, BS 5440: Part 2: should be
consulted to determine air vent requirements.
TECHNICAL DATA
Gas connection Rp
1
/
2 (
1
/
2" BSP female)
Gas supply G20 at 20 mbar.
Pressure test point Grill injector
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug.
230 - 240 a.c. 50H
Z
3A fuse
BURNER
Grill
3.6 kW
2.4 kW
150
115
Oven
HEAT INPUT
INJECTOR