DeLonghi DEGH90BG Range User Manual


 
15
MINIMUM BURNER SETTING ADJUSTMENT
Check whether the ame spreads to all burner ports when the burner is lit with the gas
tap set to the minimum position. If some ports do not light, increase the minimum gas rate
setting.
Check whether the burner remains lit even when the gas tap is turned quickly from the
maximum to the minimum position. If the burner does not remain lit, increase the minimum
gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
using a screwdriver turn screw “A” until the ame setting is correct (g. 11).
Auxiliary, Semi-rapid and Rapid burner
Normally for ULPG fully tighten the adjustment screw.
Triple-ring burner (only for the models DEGH70BG, DEGH90BG)
Normally for ULPG fully tighten the adjustment screw, then turn the screw 3/8 anti-
clockwise.
LUBRICATING THE GAS TAP
If a gas tap is difcult to turn, disassemble it, clean it carefully with petrol and spread a little
high-temperature-resistant grease on it.
These operations must be performed by an Authorized person/Service agent.
Note: Servicing of this appliance is only to be carried out by Authorised Person.
A
Figure 11