Electrolux 316495005 Microwave Oven User Manual


 
E
30
Charcoal Filter
Charcoal Filter, which was installed in your Over
the Range Microwave Oven, is used for nonvented,
recirculated installation. The filter should be changed
every 6 to 12 months depending on use.
1. Disconnect power to the Over the Range Micro-
wave Oven at the circuit breaker panel or by
unplugging.
2. Remove the two louver mounting screws and
push down carefully on the tab at each end of
the louver to disengage it. (See illustration.)
3. Pull the louver away from the unit.
4. Change the charcoal filter.
5. Carefully push the louver back into place (engag-
ing both the bottom and top tabs) and replace
the screws removed in step 2.
Louver
Top tab
Bottom tab
Screw
Screw
Charcoal filter
(white side
faces front)
Light bulbs
1. To replace light bulbs, first disconnect power
to the oven at the circuit breaker panel or by
unplugging.
2. To release cover, remove the screw on the light
cover. (See illustration.)
3. Replace light bulbs with equivalent watt bulb
available from your Electrolux Authorized Servicer
or parts distributor. Bulbs are also available at
most hardware stores or lighting centers. DO
NOT USE A BULB LARGER THAN 30 WATTS.
4. Close light cover and secure with screw removed
in step 2.
Light cover
Screw
Light
bulbs
CAUTION
Light cover may become very hot. Do not touch
glass when light is on.