Electrolux 49002VMN Convection Oven User Manual


 
B
60 mm
50 mm
A
60 mm
A
50 mm
1.
Set the correct height and area for
the appliance before you attach the
anti-tilt protection.
2.
The anti-tilt protection has two parts
(A+B). You can find the anti-tilt pro-
tection (B) on the right or left side of
the rear wall of the appliance (See fig.
1). You must install the anti-tilt protec-
tion (A) on the wall. The distance of
the hole of the anti-tilt protection (A)
from the floor is about 816 mm. Make
sure you install the anti-tilt protection
(A) at the correct height. Screw it into
the solid material or use applicable
reinforcement.
3.
Check that the anti-tilt protection fits
minimum 20 mm into the hole in rear
wall of the appliance (B) when you
push the appliance (See fig. 2). Put
the appliance in the middle of the
space between the cupboards. If the
space is larger than the width of the
appliance, you must adjust the side
measurement. Make sure that the sur-
face behind the appliance is smooth.
ELECTRICAL INSTALLATION
The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety information".
This appliance is supplied without a main
plug or a main cable.
Applicable cable types: H07 RN-F, H05
RN-F, H05 RRF, H05 VV-F, H05 V2V2-F
(T90), H05 BB-F.
COVERING TERMINAL BOARD
The recommended cross-section area is
six square millimetres (6 mm²).
When you refit the mains terminal cover,
make sure that the lower tabs are located
inside the bottom edge of the aperture,
before you fix the two screws into the top
edge of the mains terminal cover.
Make sure that the cover is securely fas-
tened.
To open the cover of terminal
board obey the procedure in op-
posite sequence.
38