22 electrolux INSTALLING THE COOKER HOOD
EN
Recirculation
The cooker hood is supplied specifi ed
for use in the recirculation mode, with
the charcoal fi lter fi tted.
In the recirculation mode contaminated
air is passed through the charcoal fi lter
to be purifi ed and recirculated into the
kitchen through the grille outlets on
either side of the chimney.
To assemble the recirculation duct, pla-
ce the recirculation outlet connection
item 15 into the support item 7.3.
Insert the extension ducts item 14.1 into
either side of the recirculation outlet item
15 ensuring the connections are verti-
cally and horizontally aligned with the
outlets in the chimney.
Connect the recirculation oulet item 15
to the outlet on top of the hood body
using either a piece of Ø125mm or
Ø150mm fl exible or rigid pipe.
Rigid pipe is strongly recommended
and should be used where possible as
this will ensure the best performance
while lowering noise.
14.115
7.3
ø 150