Electrolux JLBIHD906 Ventilation Hood User Manual


 
8
Recirculation Mode
The cooker hood is supplied specified for use in the recircula-
tion mode, with the charcoal filter fitted.
In the recirculation mode contaminated air is passed through
the charcoal filter to be purified and recirculated into the kitch-
en through the grille outlets on either side of the chimney.
Assemble the two halves of the ducting extension pipe
item 14.
Push-fit the extension pipe onto the ducting spigot on
top of the canopy.
Push-fit the recirculation adapter item 15 on to extension
pipe item 14.
Insert the recirculation outlet extensions item 14.4 into
the recirculation adapter item 15.
The recircualtion grilles item 8a and 8b must be fitted
after the lower chimney item 2.2 has been fitted.
Ensure the activated charcoal filter has been fitted.
Chimney Stack
The chimney consists of two sections.
The lower chimney measures 740mm and the upper chim-
ney (with the recirculation grilles on either side) measures
215mm. The overall installed measurement is min. 740
- max 940mm.
Fitting the Chimney
Position the upper chimney section and fix the upper
part to the frame using the 2 screws 12c (2,9 x 9,5)
provided.
Similarly, position the lower chimney section and fix the
lower part to the frame using the 2 screws 12c (2,9 x
9,5) provided.
When installed in the recirculation mode the ducting outlet
extension pieces 14.1 should align with the rectangular
holes in each side of the chimney.
Position the recirculation grilles 8a and 8b so the slats
face in a forwards and upwards direction.
Fitting the Hood Body
Before fixing the hood body to the frame:
Pull the Comfort Panel to open it.
Disconnect the panel from the hood canopy by sliding
the fixing pin lever.
Remove the grease filters from the hood body.
Remove any activated charcoal filters.
From below, use the 4 screws 12f (M6 x 10)







