Recirculation Mode
The cooker hood is supplied specified for use in the recircula-
tion mode, with the charcoal filter fitted.
In the recirculation mode contaminated air is passed through
the charcoal filter to be purified and recirculated into the kitch-
en through the grille outlets on either side of the chimney.
• Assemble the two halves of the ducting extension pipe
item 14.
• Push-fit the extension pipe onto the ducting spigot on
top of the canopy.
• Push-fit the recirculation adapter item 15 on to extension
pipe item 14.
• Insert the recirculation outlet extensions item 14.4 into
the recirculation adapter item 15.
• The recircualtion grilles item 8a and 8b must be fitted
after the lower chimney item 2.2 has been fitted.
• Ensure the activated charcoal filter has been fitted.
Chimney Stack
The chimney consists of two sections.
The lower chimney measures 740mm and the upper chim-
ney (with the recirculation grilles on either side) measures
215mm. The overall installed measurement is min. 740
- max 940mm.
Fitting the Chimney
• Position the upper chimney section and fix the upper
part to the frame using the 2 screws 12c (2,9 x 9,5)
provided.
• Similarly, position the lower chimney section and fix the
lower part to the frame using the 2 screws 12c (2,9 x
9,5) provided.
• When installed in the recirculation mode the ducting outlet
extension pieces 14.1 should align with the rectangular
holes in each side of the chimney.
• Position the recirculation grilles 8a and 8b so the slats
face in a forwards and upwards direction.
Fitting the Hood Body
• Before fixing the hood body to the frame:
• Pull the Comfort Panel to open it.
• Disconnect the panel from the hood canopy by sliding
the fixing pin lever.
• Remove the grease filters from the hood body.
• Remove any activated charcoal filters.
• From below, use the 4 screws 12f (M6 x 10)