Electrical Connections
Electrical Requirements
Any permanent electrical installation must comply with the
latest I.E.E. Regulations and local Electricity Board regulations.
For your own safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate inside
the cooker hood.
Remove the grease filters (see paragraph Maintenance)
being sure that the connector of the feeding cable is
correctly inserted in the socket placed on the side of
the fan.
Push fit the Cmd connecter on the cable from the motor
housing to the one from the control box.
Connect the lights connector Lux.
Place both the Lux and Cmd connectors in the junction
box 24 and close it using the two screws 12e (2,9 x 9,5)
provided.
Fix the junction box to the hood body using the two
screws 12c (2,9 x 6,5) provided.
For the recirculation version, fit the activated charcoal
odour filter.
Replace the grease filters.
This appliance is fitted with a 3 core mains cable and must
be permanently connected to the electricity supply via a
double-pole switch having 3mm minimum contact gap on
each pole. A Switched Fuse Connection Unit to BS1363 Part
4, fitted with a 3 Amp fuse, is a recommended mains supply
connection accessory to ensure compliance with the Safety
Requirements applicable to fixed wiring instructions.
This appliance conforms to BS 800: 1988 and EEC Directive
No. 78 308 regarding suppression of radio and television
interference.
THIS APPLIANCE MUST BE EARTHED




