Electrolux PLHV36W7CC Ventilation Hood User Manual


 
5
C
L
min.
29 15/16
Template
Ceiling
Bracket
CEILING
Hooks
Lower
Fastener
Locations
Upper
Fastener
Locations
Installation
Preparation of mounting surface (Drywall)
1. Select a mounting height comfortable for the user and mark on wall behind
cooktop.
2. Mark center line of cooktop and draw vertical line from bottom of hood to the
ceiling.
3. Tape template, matching center-line and hood bottom as shown in Fig. 2.
Distance from bottom of template to the ceiling must be minimum 29 15/16.
4. Mark centers of the 6 fastener locations through template on wall then remove
template.
5. Mark wall with horizontal line 1" above highest and 1" below lowest fastener
location.
6. Find studs behind drywall by tapping wall or using a stud finder.
Mark the center of the studs with a vertical line to the right and left of the
marked fastener location.
Note: Each 2 x 6 must span at least 2 studs side to side.
7. Cutout drywall along marked lines.
Install each 2 x 6 between studs firmly flush with stud front. Make sure all
mounting screws will anchor to added lumber. Replace drywall and refinish.
8. Remark center line and hood bottom on same location as before and tape
template on wall as in step 3 above.
9. Mount 2 mounting hooks with wood screws (supplied in mounting hardware kit)
on locations marked on template, then remove template.
10. Install duct cover ceiling bracket to wall flush to ceiling with drywall anchors
supplied.
Figure 2
Tools required for installation
Screw driver
(flat head, pozidrive n°2 and torx 10)
Allen key 4mm
Electric drill with twist bit Ø 10 mm