Emerson h990 Beverage Dispenser User Manual


 
A
Select a spot under the sink to mount
tank vertically within reach of both
plumbing and electrical connections.
The tank should be within 16" or less
of faucet water lines and within 30"
or less of a standard grounded outlet.
While holding tank in place on
the spot selected for installation,
use a pencil to mark locations for
2 hanging screws.
Property Damage: Tank must be located within 16" of
faucet and within 30" or less of a standard grounded
outlet. DO NOT extend plumbing or electrical lines.
3
Without depressing the gray button,
place the snap-connect fitting at
the end of the blue 1/4" tube onto
the left fitting on the tank, pushing
until it clicks into place. (1)
Slip the flexible white 7/16" tube
over barbed middle fitting and slide
down approximately 1/2". (2)
Slip the clear 5/16" tube over the far
right smooth fitting and slide down
approximately 1/2". (3)
Visually check for pinched or
crimped tubes.
4
A
Property Damage: Pinched or blocked water lines
may cause damage to the dispenser tank.
Tank must be
mounted level
to ensure
proper operation.
Hose clamps are not needed for any
of the connections.
Mount tank vertically in an area that
allows clearance on the underside of the
tank for drainage,if necessary.
DO NOT over tighten screws.
Pre-drill 1/8" pilot holes at marks.
Turn screws into pre-drilled holes,
leaving 1/4" exposed.
Hang the tank on the screws.
Tighten the screws with only 1/2 turn
clockwise.
B
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
Leave 1/4" for
hanging tank.
Property Damage: Check to make sure
tubes are connected properly and are
pushed down as far as possible.
(1) (2) (3)
MOUNTING THE TANK
CONNECTING FAUCET TO TANK
Property Damage: Do not pinch or break copper
tubing. Do not distort the last 1 inch of tubing.
Make sure to use fiber gasket
to ensure proper seal.
Unpack dispenser components.
On a firm, flat surface, carefully
straighten the copper tubing using
hands only.
Ensure that the fiber gasket is
properly seated against the base
of the dispenser head.
2
B
A
Fiber
Gasket
H770
H770
From below the sink, place semi-
circular metal mounting plate over
the mounting screw, ensuring the
mounting plate covers the sink hole.
Slide washer over so that the screw
is now inside the smaller hole.
Tighten the screw until snug.
Feed tubes down the hole in the sink
or countertop until the base is at rest
on the sink or countertop surface.
Position faucet head at the
desired angle.
Half moon shaped metal mounting plate
should cradle all descending tubes.
An assistant may be needed to hold
the dispenser head in place
while securing the dispenser.
C
D
H770
H770
DO NOT remove mounting screw or
fiber gasket from base of dispenser.
8
INSTALLING THE FAUCET - H770
9