Everpure 327 Water Dispenser User Manual


 
Cold Drink Center (327/328) Operator’s Guide
3280020 Page 1 August, 2003
Initial Set-up
Power Requirements
This merchandiser requires power as shown in the following table. NOTE: Each
merchandiser should have its own electrical circuit.
This merchandiser is supplied with a service cord for the country of use and is ter-
minated in a grounding type plug. The wall receptacle used for this merchandiser
must be properly polarized, grounded, and of the correct voltage. Operating the
merchandiser from a source of low voltage will VOID YOUR WARRANTY. Each
merchandiser should have its own electrical circuit and that circuit should be pro
-
tected with a circuit breaker or fuse conforming to local regulations.
Voltage Check - Place the leads of a voltmeter across the LINE (LIVE) and NEU-
TRAL terminals of the wall receptacle. The voltmeter should indicate 110-130
volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz loca
-
tions.
Polarity Check - Place the leads of a voltmeter across the LINE (LIVE) and
GROUND terminals of the wall receptacle. The voltmeter should indicate 110-130
volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz loca
-
tions.
Noise Potential Check - Place the leads of a voltmeter across the NEUTRAL and
GROUND terminals of the wall receptacle. The voltmeter should indicate 0 volts
ac. A measurement greater than 1.5-2.0 volts ac could result in problems for the
merchandiser's electronic circuitry caused by electrical noise.
Any deviation from these requirements could result in unreliable performance
from your merchandiser.
Water Requirements
If your location has chemically softened water, one of the following steps is
advised:
Have a non-softened supply line run to the merchandiser
Contact your local water filter supplier for information and suggestions
Well water can also be used in the Cold Drink Center. However, you should have
it checked for levels of carbonates and alkalies. Contact your water filter supplier
if these values are relatively high.
Water Pressure
Minimum water pressure: 20 psi (138.0 KPa) at 1/2 gallon/minute
Maximum water pressure: 80 psi (522.0 KPa) at 1/2 gallon/minute
Power Requirements
Country Volts Frequency (Hz) Current (Amps)
U.S., Mexico, and Canada 115 60 20
International 230 50 13 - 16