Everpure 327 Water Dispenser User Manual


 
Cold Drink Center (327/328) Operator’s Guide
3280020 Page 71 August, 2003
The keyswitch input is active and configured as an inhibit.
Configuration error; displays the machine configuration screen.
NOTE: this is the actual config screen. You may enter the cor-
rect config number directly on this screen without further
action.
The cup ring is jammed.
Cup turrets are jammed
Out of cups.
The waste pail is full.
The automatic delivery door is jammed.
Coin mech not detected - machine will not operate if config-
ured for coin mech.
Incomplete coin mech communications — check harness.
Coin mech reporting a bad tube sensor — replace mech.
Replace the coin mechanism.
Coin mechanism acceptor section is unplugged from the main
body of the coin mech. Connect the cable and cycle machine
power OFF and then ON.
One or more coin tubes are jammed. Pay a coin from each
tube until the jam is cleared.
Card reader reporting error — machine will not operate if con-
figured for DEBIT ONLY.
Bill validator reporting error — machine will not operate.
Empty stacker, clear jams, etc.
Incomplete bill validator communications — check harness.
One of the motors has failed. The unit will disable itself until
the error is corrected. Check for bill stuck in the acceptance
path. If no bill is present, replace the validator. Cycle machine
power OFF and then ON.
One of the sensors in the bill validator has failed. The unit will
disable itself until the error is corrected. Check for bill stuck in
the acceptance path. If no bill is present, replace the validator.
Cycle machine power OFF and then ON.
A bill is jammed in the acceptance path. The unit will disable
itself until the error is corrected. Remove bill stuck in the
acceptance path. Cycle machine power OFF and then ON.
The stacker is open or removed. The unit will disable itself
until the error is corrected. Install the stacker correctly.
Price error detected and changed to maximum - check prices.
All selection keys are locked out.
All selections are reported out of service.
Cup ring 1 is out of service due to a SureVend™ error.
Cup ring 2 is out of service due to a SureVend™ error.