INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Australia

The restraining chain must be fitted.
The length of chain between the appliance and the wall
fixing should prevent strain on the gas and electricity
connections, but still allow access to unhook the chain
when the cooker is pull forward.
Fix the supplied hook securely to the wall.
Measure the length of chain required. Use the hexagon-
headed screw, washers and bolt supplied in the
restraining chain kit to fix the chain to one of the holes
at the top of the flue trim bracket:




Hook the other end of the chain to the wall fixing:
Gas Connection
The Gas supply needs to terminate with a down facing
bayonet. The rear cover boxes limit the position of the
supply point.
View from the rear
A Position for gas supply connector
B Appliance gas inlet
Because the height of the cooker can be adjusted
and each connection is different, it is difficult to
give precise dimensions. Ideally, the house supply
connection should be in the shaded area shown in
the above diagram. A means of isolation must be
provided at the supply point by either an approved
quick-connect device or a Type 1 manual shut-off
valve. The hose should be fitted so that both inlet and
outlet connections are vertical so that the hose hangs
downwards in a ‘U’ shape.
The connector is located below the hotplate level at the
rear of the cooker.
A flexible connection is supplied with the cooker, and
it is with this in mind that the stability bracket and
restraining chain have been supplied.
If it is necessary to use another hose, it must be to A.S.
1869 Class B standard and suitable for your gas type
(if in doubt, contact your supplier). Even if you do use